An Entirely New Species
The uMR® Jupiter 5T represents a real breakthrough in the evolution of MRI, in which the brand-new 5.0T superconducting magnet and RF system are designed using state-of-the-art technology. Custom sequences are developed to achieve entirely new levels of innovation. It allows you to explore new frontiers in ultra-high field (UHF) MRI by enabling exclusive whole-body 5.0T clinical and research applications. A new species of whole-body MRI says hello to the world.
Unprecedented Ultra-definition Imaging
- Revolution Made Real
- All-in-one Solution for Clinical and Translational Research
- Revolution Made Seamless
- Raise the Field Strength without Raising the Fringe Field
- Revolution Made Accessible
uAIFI Inside
Empowered by the uAIFI Technology Platform, the potential for uMR® Jupiter 5T is even more anticipated with significant performance enhancements, more powerful imaging capabilities, better workflow, and improved user experience.
Unique 8ch Volume Transmit Coil
The 8-channel independently controlled RF transmission architecture allows for dynamic real-time B1 field calibration for different patients, including the amplitude, phase, and waveform of the RF pulse. It effectively solves the problem of UHF B1 inhomogeneity to achieve uniform excitation of the human body, bringing whole-body UHF MR imaging into a clinical setting for the first time.
World's First Whole-body UHF MR Imaging
In the field of UHF MRI, there has been a great deal of attention paid to achieving perfect compatibility between clinical diagnosis and research exploration. To make a difference, the uMR® Jupiter 5T addresses the three major challenges facing UHF MRI: RF B1 field inhomogeneity, RF safety, and high siting requirement. It will lead to a new era in UHF imaging that will facilitate precise diagnosis and mechanism studies of whole-body diseases, including those of the heart, abdomen, pelvis, and many others.
Ultra-high Performance Gradients
- 3.5 MW Peak Power: Whole-body UHF MRI gradient performance is now improved to an entirely new level thanks to our state-of-the-art gradient power amplifier, developed in-house by United Imaging.
- 120 mT/m & 200 T/m/s: Significantly increase the power of diffusion-weighted imaging and functional MRI with outstanding accuracy and stability for brain research.
High-resolution DTI
- 5.0T High-resolution DTI clearly shows U-fibers that are not visible on conventional 3.0T.
Accurate BOLD
- 5.0T High-resolution BOLD more accurately shows the distribution of activated areas on the deep cortex.
Groundbreaking 5.0T Magnet Technology
- 0.015 ppm @20 DSV Homogeneity and 1.3 ppm @50 DSV Homogeneity powered by 5.0T Magnet Technology.
- Remarkable Homogeneity facilitates whole-body clinical and research applications.
UHF MRI with Low Siting Requirement
The system installation requirements are comparable to those of a conventional 3.0T MRI thanks to its innovative magnet architecture with optimized active shielding design, which makes UHF MRI deployment easier than ever.
Advance Your Clinical Dimensions
- TOF MRA: 3.0T vs. 5.0T with the same scan parameters.
- SWI: 3.0T vs. 5.0T with the same scan parameters.
- Hippocampus: 3.0T vs. 5.0T with the same scan parameters.
- Kidney: 3.0T vs. 5.0T with the same scan parameters.
- Prostate CSI 3D: 3.0T vs. 5.0T with the same scan parameters.
Clinical Application
- Neurology
- Abdominal Imaging
- Cardiac Imaging
- Orthopedics
Voxel Sizes
- T1W GRE FSP 3D: 0.7×0.7×0.7 mm³
- T2W FLAIR MATRIX 3D: 0.5×0.5×0.5 mm³
- T2W FSE TRA/COR: 0.25×0.25×2 mm³
- ASL 3D: 0.7×0.7×0.7 mm³
- DTI: 1×1×1 mm³
Body Imaging Examples
- Pancreas T2W FSE FS TRA MicroView
- Prostate T2W FSE FS TRA
- Cardiac Imaging
- Knee T1W FSE SAG
- Shoulder PDW FSE FS COR
- Ankle PDW FSE FS SAG
- L-spine T1W FSE SAG
- Whole-spine Imaging